Manufacturer Capillary Column Cross Reference
Use the chart below to cross reference manufacturers' stationery phases as
well as USP method designations to Alltech equivalent columns. Slight variations
in selectivity may result between different manufactures' columns.
| Composition |
Alltech |
Page No |
USP Designation |
Similar Phases |
| 100% Dimethylpolysiloxane |
ATTM-1
ECTM-1 |
52 |
G1,
G2, G38 |
007-1, CP-Sil 5CB,
DBTM-1, DB-1ht, HPTM-1, HP-101, OVTM-1,
RSLTM-150,
RSL-160, RtxTM-1, SE-30TM, SPBTM-1,
SFB-Sulfur, ULTRATM-1, SP-2100,
BP-1, DC-200, PE-1, ZB-1 |
5% Phenyl equivalent
Polysilphenylene-Siloxane |
ATTM-5ms |
62 |
|
DBTM-5ms, RtxTM-5Sil ms,
BPX-5, 007-5ms, HPTM-5TA |
(5% Phenyl) -
95% methylpolysiloxane |
ATTM-5,
ECTM-5 |
63 |
G27, G36 |
007-2, CF-Sil 8CB,
DBTM-5, DTMB-5.625, DBTM-5ht, HPTM-5,
HPTM-5ms,
0VTM-5, PTE-5,
PTE-5QTM, PAS-5, RSL-200, RtxTM-5,RtxTM-5ms,
SAC-5, SE-54, SPB-5, ULTRA-2, XTI-5, SE-52, BP-5, PE-2, ZP-5 |
(20% Phenyl) -
80% methylpotysitoxane |
ATTM-20,
ECTM-20 |
70 |
G28, G32 |
007-7, RtxTM-20, SPB-20, VOCOL, PE-7 |
(35% Phenyl) -
65% methylpolysiloxane |
ATTM-35 |
71 |
G42 |
007-11, DBTM-35,
DBTM-35ms,
HPTM-35, RSL-300, RtxTM-35,
SPB-35,
SPB-608, OVTM-11,
PE-35, Sup-Herb |
(50% Phenyl) -
50% methylpolysiloxane |
ATTM-50 |
72 |
G3 |
007-17, DB-17,
DB-17ht, HPTM-17,
HPTM-50+, OVTM-17, RtxTM-50,
SP-50, SP-2250, SPB-50, CP Sil 24CB, PE-17, ZB-50 |
(6%
Cyanopropyiphenyl)-
94% methylpolysfioxane |
ATTM-624, ATTM-1301 |
74
72 |
G43 |
007-1301, DBTM-624, DBTM-1301,
HPTM-1301, HPTM-624, RtxTM-1301,
RtxTM-624, SPB-1301, SPB-624, 007-624, ZB-624 |
(14%
Cyanopropyiphenyl)
86% methytpotysitoxane |
ATTM-1701 |
72 |
|
007-1701, CP-Sil
19CB, DB-1701, HPTM-1701,
OVTM-1701, PAS-1701,
RtxTM-1701, SPB-1701, BP-10, ZB-1701 |
| Trifluoropropylmethyl polysiloxane |
ATTM-210 |
72 |
G6 |
DBTM-210, RSL-400,
RtxTM-200, OVTM-202, OVTM-210, 0VTM-215,
QF-1,
SP-2401 |
(50% Cyanopropylphenyl)
50% methylpolysiloxane |
ATTM-225 |
75 |
G7 |
007-225, CP-Sil43CB,
DBTM-225, HPTM-225,
0VTM-225, RSL-500, RtxTM-225,
BP-225, PE-225 |
(50% Cyanopropyl)
50% methylpolysiloxane |
ATTM-SILAR |
75 |
G5 |
DBTM-23, 007-23, PE-23,
RtxTM-2330, SF 2330 |
| Polyethyleneglycol |
ATTM-WAX,
ECTM-WAX |
76 |
G14, G15, G16, G20, G39 |
007-CW, Carbowax®
20M, CP-Wax 52CB, DBTM-WAXetr,
DBTM-WAX,
RtxTM -WAX,
HP-20M, HPTM-Wax,
InnowaxTM,
Omegawax, Stabilwax®, SUPELCOWAX®-l0, SUPEROX® II,
BP-20, ZB-WAX |
| Base Modified Polyethyleneglycol |
ATTM-CAM |
84 |
|
Stabilwax®-DB, CAM, Carbowax® Amine, CP Wax 51 |
| Acid Modified Polyethyleneglycol |
ATTM-1000,
ECTM-1000 |
84 |
G25, G35 |
007-FFAP, CP-Wax 58CB, DBTM-FFAP, HPTM-FFAP,
NukolTM,
0VTM-351, SP-1000, Stabilwax-DA,
SUPEROX-FA, BP-21 |
| Specialty Phases
|
| PONA Analysis |
ATTM-Petro |
89 |
|
007-1-100-0.5F, CP-Sil PONA GB,
DBTM-Petro100, Petrocol DH, PONA,
Rtx-1PONA, HP-PONA |
| ASTM Method 2887 |
ATTM-2887 |
89 |
|
007-1-10V-1.0F, DBTM-2887,
Petrocol 2887, Petrocol EX2887, Rtx-2887, Sim-Dist-CB |
| ASTM Method 3710 |
ATTM-3710 |
89 |
|
Petrocol 3710 |
| EPA Method 608 |
ATTM-Pesticide |
88 |
|
007-608, DBTM-608,
HPTM-608,
SPB-608 |
| EPA Method 502.2 |
ATTM-502.2 |
88 |
|
007-624, 007-502, DB-502.2, DBTM-VRX, HPTM-624, HPTM-V0C,
MST-502.2, MXT-624, MXT-Volatiles, OV-624, Rtx-502.2, RtxTM-624, RtxTM-Volatiles,
VOCOL |
| Sulfur Analysis |
ATTM-Sulfur |
89 |
|
SPB-1 SULFUR |
| Amines |
ATTM-Amines |
89 |
|
None |
| Alltech offers three lines of
capillary columns to suit every application and budget; Econo-Cap™,
Heliflex®, and Multi-Cap®. Econo-Cap™
Columns are batch tested to dramatically reduce the price without
sacrificing quality. Heliflex® Columns are Alltech’s premium
line of individually tested capillary columns. Both the Heliflex®
and Econo-Cap™ lines are manufactured under identical
conditions using the same high quality polyimide coated fused silica and
immobilized stationary phases. In addition each are mounted on a rugged
cage.
Multi-Cap®Columns are Alltech’s exclusive line
of capillary columns designed for applications that demand maximum
throughput and/or speed. Compared to traditional capillaries, Multi-Cap®
Columns overcome small diameter column flow, volume, and sample
capacity restrictions while generating superior chromatographic results.
Regardless of the capillary line you choose, every Alltech manufactured
capillary column has an unconditional guarantee of column performance.
Econo-Cap™ Capillary Column Line
 |
Best Value in Capillary Columns Anywhere |
 |
Batch Tested to Dramatically Reduce Price |
 |
Ideal for Aggressive Applications |
 |
Available in the Most Popular Phases |
We’ve taken our most popular capillary columns and perfected the
manufacturing procedure to the point that reproducibility is assured. This
allows us to test these columns in batches instead of individually, while
still offering an unconditional guarantee. Batch testing significantly
reduces cost in production without sacrificing quality. |
Econo-Cap™ Capillaries
are manufactured under identical conditions using the same high quality
fused silica and rugged cage as our line of individually tested Heliflex®
Capillary Columns. Each Econo-Cap™ Capillary Column
comes with a copy of the batch test results, an instruction manual, and
capillary end caps. If you are not completely satisfied with the quality
of your Econo-Cap™ Capillary Column it will be replaced at no
charge.
Note: Column nuts and ferrules are not included.
Heliflex® Capillary Column Line
 |
High Performance Individually Tested Column |
 |
Choice of 5’ or 7" Rugged Cage |
 |
Most Complete Selection of Phases |
 |
Custom Columns Available to Suit Your Specific Application |
Heliflex® Capillary Columns are manufactured from the
highest quality polyimide coated synthetic fused silica. They are mounted
on a rugged wear-resistant cage. Choose from a wide variety of phases and
dimensions to suit your specific requirements. If the column you need is
not available in our standard offering, request a custom Heliflex®
Column made to your individual specifications. Each Heliflex®
Column is individually tested to guarantee column performance and comes
with a test chromatogram, instruction manual, capillary end caps, and a
free ceramic column cutter.
Note: Column nuts and ferrules are not included. |
|