ChromaluxTM HB Luminescent Assay Microplates - Flat Bottom

Chromalux HB plates are reflective, densely pigmented and molded from white polystyrene. They enhance the sensitivity of luminescent reactions by increasing signal reflectivity and minimizing cross-talk. They are treated to provide a uniformly, high binding surface for luminescent immunoassay (LIA) and may reduce the potential for static discharge in "Flash" assays. These microplates are RNase and DNasefree and are non-pyrogenic.

ImmuluxTM Immunoassay Microplates - Flat Bottom

Immulux polystyrene immunoassay plates are untreated, and offer consistent medium binding pertormance with typical affinity for hydrophobic complexes and proteins in Enzyme-Linked Immunosorbent Assay (ELISA). These microplates are RNase and DNase-free and are nonpyrogenic

ImmuluxTM Immunoassay Microplates - "U" Bottom

Immulux HB polystyrene immunoassay plates are treated, and offer consistent high binding perlormance with typical affinity for hydrophilic complexes and proteins in Enzyme-Linked Immunosorbent Assay (ELISA). These microplates are RNase and DNase-free and are nonpyrogenic.

DYNEX Technologies’ Microplate Luminometer Reference Plate

The DYNEX Technologies Luminometer Reference Plate is designed for monitoring the precision and accuracy of the Relative Light Unit (RLU) measurement for most microplate Luminometers. It consists of a precision controlled light source that is filtered to produce a narrow bandwidth of light thus ensuring reproducibility. The reference plate is powered by two 1 .5v AAA alkaline batteries.

The Luminometer Reference Plate spans 4 decades of instrument measurement from 0.3 to 500 RLU and has an easy-to-use design that consists of two toggle switches that control the ON/OFF function and HIGH/LOW output from the plate. The adjustment of the reference plate is independent of the Luminometer and is achieved by using a unique, highly stable non-PMT-based detector.

Opsys MRTM Verification Plate

The Opsys MR Verification Plate is used to verify correct measurement pertormance of your Opsys MR Absorbance Reader. The Opsys MR Verification Plate performs Alignment, Accuracy, Linearity and Precision tests of your Opsys MR at several wavelengths. The Verification Plate is supplied with Absorbance calibration data traceable to NIST primary standards and NAMAS (through NPL).

MRX® Verification Plate

The MRX Verification Plate includes software for automating its use with the MRX 11 photometer. The MRX Revelation photometer comes with preinstalled software for automated data collection and reporting from the MRX Verification Plate. The plate provides the means to verify physical alignment (X- and Y-alignment and skew), optical channel matching, correct filter installation, photometric linearity and photometric accuracy. The absorbance values at 450 nm of the neutral density filters in the MRX Verification Plate are traceable to the National Institute of Standards and Technology (NIST). Calibration for other wavelengths is available upon request.

 

"Our workshop services all of the above equipment"  