A02- Liquid Chromatography

High-pressure Gradient System |

Isocratic System |
Descriptions
|
High-pressure Gradient System
|
|
|
|
A. |
High-pressure pump: 2 pcs |
B. |
High-pressure pump: 2 pcs |
|
|
UV/VIS detector: 1 piece |
|
Diode array detector: 1 piece |
|
|
High-pressure 6-port injector: 1 piece |
|
High-pressure 6-port injector: 1 piece |
|
|
C18 column 5 µm
ID4.6
×
200mm: 1
piece |
|
C18 column 5µm ID4.6
×
200mm: 1
piece |
|
|
Gradient control module: 1 unit |
|
Gradient control module: 1 unit |
|
|
High-pressure gradient mixer: 1 piece |
|
High-pressure gradient mixer: 1 piece |
|
|
Single channel chromatography data system: 1 unit
|
|
DAD Data-Processing Software: 1 unit |
|
Isocratic System |
|
|
|
A. |
High-pressure pump: 1 piece |
B. |
High-pressure pump: 1 piece |
|
|
UV/VIS detector: 1 piece |
|
Diode array detector: 1 piece |
|
|
High-pressure 6-port injector: 1 piece |
|
High-pressure 6-port injector: 1 piece |
|
|
C18 column 5µm ID4.6
×
200mm: 1
piece |
|
C18 column 5µm ID4.6
×
200mm: 1
piece |
|
|
Single channel chromatography data system: 1 unit
|
|
DAD Data-Processing Software: 1 unit |
Features & Specifications
P230 High Pressure Pump (Analytical)
Features
Specifications
 |
Flow range: 0.001-9.999mL/min, with 0.001mL/min increment |
 |
Flow accuracy: ± 0.3% (1.000mL/min, 8.5MPa, water, ambient temperature) |
 |
Flow stability: RSD 0.1% (1.000mL/min, 8.5MPa, water, ambient
temperature) |
 |
Max pressure: 40MPa (0.001-4.999mL/min); 20MPa (5.000-9.999mL/min) |
 |
Pressure precision: the displayed pressure error is less than ± 0.3%; |
 |
Pressure pulsation: l 1.0% |
 |
Power requirements: 110/220V, 60/50Hz |
 |
Power consumption: 180W |
 |
Dimensions: 420mm × 280mm × 175mm |
 |
Weight: 20kg |
UV230+ UV/Vis Detector
Features
Specifications
 |
Wavelength range: 190-720nm |
 |
Light source: Deuterium lamp and Tungsten lamp |
 |
Optical bandwidth: 6nm |
 |
Wavelength accuracy: ±0.5nm |
 |
Wavelength repeatability: ±0.1nm |
 |
Wavelength programmable time setting range: 0.1-999.9min |
 |
Rise Time: 0.0-9.9s |
 |
Linear range:
≥1.5AU (5%) |
 |
Baseline noise:
≤±3 × 10-5 AU (empty cell, 254nm, 1.0s) |
 |
Baseline drift:
≤5 × 10-4AU/h (empty cell, 254nm, time: 60min) |
 |
Analytical flow cell :optical path length 10mm; volume 10µL |
 |
Semi-preparative flow cell: optical path length 3mm; volume 5µL |
 |
Micro flow cell: optical path length 3mm; volume 1.2µL |
 |
Power requirements: 110/220V, 60/50Hz |
 |
Power consumption: 110W |
 |
Dimensions: 420mm × 280mm × 175mm |
 |
Weight: 8kg |
DAD230 Diode Array Detector
Features
Specifications
 |
Wavelength Range:
199-618nm (512 Diodes)
190-1015nm (1024 Diodes) |
 |
Light source: Deuterium lamp and Tungsten lamp |
 |
Number of Diodes: 512/1024 |
 |
Array Resolution: 0.8nm |
 |
Spectral Resolution: 1.2nm |
 |
Wavelength Accuracy: ±0.5nm |
 |
Wavelength Repeatability: ±0.1nm |
 |
Rise Time: 0.1-9.9s |
 |
Baseline Noise: < ± 1.5 × 10-5 (AU); N2 in empty cell, 254nm, 1.0s |
 |
Baseline Drift: < 5 × 10-4 (AU/h) N2 in empty cell, 254nm, time: 60min |
 |
Flow Cell:
Analytical flow cell :optical path length 10mm; volume 10µL
Semi-preparative flow cell: optical path length 3mm; volume 5µL |
 |
Micro flow cell: optical path length 3mm; volume 1.2µL |
 |
Operating Temperature: 4 to 40°C |
 |
Operating Humidity: < 80%, non-condensing |
 |
Power requirements: 110/220V, 60/50Hz |
 |
Power Consumption: 110W |
 |
Dimensions: 420mm × 280mm × 180mm |
 |
Weight: 8kg |
DAD Data Working Station
| To guarantee DAD system a stable operation under Windows 9x, we adopt
virtual driver. With a friendly interface and strong function DAD
data-processing platform, users can conveniently observe and process contour
map, spectrogram, chromatogram and three-dimensional
spectrogram-chromatogram. With sufficient functions of chromatographic data
processing and quantitative calculating, arbitrary revolving and parts
magnifying, users can obtain more vivid visual effect and results analysis. |

|
DAD workstation can provide all kinds of chromatograms, including single
wavelength, arbitrary two-wavelength absorptance, wavelength time procedure,
max absorption wavelength and total absorption, and among them, the most
sensitive detection method is max absorption wavelength chromatogram, while
the best method to quantitate reproducibility is total absorption
chromatogram. DAD system provides many discrimination methods on peaks purity, including
contour map, three-dimensional spectrogram-chromatogram, overlap
spectrogram, wavelength comparison diagram and peaks purity calculating
method. Users can conveniently built their ultraviolet spectrogram gallery with the
multifunctional spectrogram gallery managing and searching procedure, and
the
programme can auto-pick spectrogram to each peak from spectrogram,
chromatogram and three dimensional data; auto-search spectrogram gallery;
users can also add the auto-picked spectrogram into appointed gallery. |