B01- V-1200/UV-1200 Series Spectrophotometer
Descriptions |
 |
-
V1200 and UV1200 series spectrophotometer have attractive
performance for general data. As long as you use your standard sample
solution, you can get a standard curve on the large LCD screen by local
control software. In addition, you can print the curve through USB or
analog port.
-
Functions of this instrument include:
-
a) Standard Curve—At least 9 standard samples can be
used to establish a standard curve. The curve and the curve equation
will be displayed on the screen simultaneously to measure
concentration of unknown solutions by the curve.
-
b) Coefficient Method—If you have known the
coefficient of k&b of the formula C=kA+b, you can input the value and
then test the unknown solutions.
This instrument has been widely used in colleges and
enterprises for general quantitative analysis and experiments.
Features
-
Large graphic LCD display (128 × 64) to directly show
graphs on the screen, displaying a total of 50 groups of data and being
able to save the research data.
-
Pre-aligned deuterium lamp for easy lamp replacement to
avoid optical adjustment.
-
Power failure protection: Research data can be saved and
restored when there is power failure.
-
Automatically check wavelength and photometric accuracy
using validation report.
-
Powerful integrated software for data acquisition for
basic measurement and analysis.
-
Other features include spectrum test, wavelength check,
standard curve, and application software.
Specifications
|
Model |
V-1200 |
UV-1200 |
|
Optical System |
Single Beam, Grating 1200 lines/mm |
|
Wavelength Range |
325-1000nm |
200-1100nm |
|
Spectral Bandwidth |
4nm |
|
Wavelength Accuracy |
±1nm |
|
Wavelength Repeatability |
1nm |
|
Photometric Accuracy |
±0.5% T |
|
Photometric Repeatability |
0.3% T |
|
Stray Light |
0.3%T |
|
Baseline Stability |
±0.004 A/h (500nm) |
|
Display |
LCD |
(128 × 64) |
|
Photometric Mode |
T, A, E |
|
Wavelength Setting |
Automatic |
|
Photometric Range |
-0.097-2.5 A, 0-125% T |
|
Detector |
Si Photodiode |
|
Keyboard |
Membrane Keypad |
|
Light Source |
Tungsten lamp |
Tungsten & Deuterium |
|
Output |
USB Port & Parallel Port (Printer) |
|
Power Requirement |
AC 220V/50Hz or AC 110V/60Hz |
|
Dimensions |
(W × D × H) |
470 × 370 × 180mm |
|
Weight |
|
12Kg |
12Kg |
|
Packing list of UV1200
Spectrophotometer…………… 1 |
Optional accessories
SINGLE CELL HOLDER
FOR 10MM SQU.CUVT. |
|
Mains Lead…………………... 1 |
CYLINDRICAL CELL HOLDER |
|
Cuvettes……………………… Set of 4, glass |
TEST TUBE HOLDER (ø8-Ø22mm) |
|
Set of 2, quartz |
LONG PATH CELL HOLDER |
|
User Manual…………………. 1 |
4-CELL HOLDER FOR UP TO 50MM SQU.CUVETTE |
|
4-CELL HOLDER FOR UP TO 100MM SQU.CUVETTE |
|
Packing list of V-1200
|
PRINTER |
|
Spectrophotometer…………… 1 |
COMMON SOFTWARE FOR 1200
|
|
Mains Lead…………………... 1 |
|
|
Cuvettes……………………… Set of 4, glass |
|
|
User Manual…………………. 1 |
|
|
|
B01- 1600/1800 Series Spectrophotometer
Descriptions |

|
-
1600/1800 Series are developed for precise test for
its stray light is only 0.05%T.
-
This series have benefits of flexible, user-friendly,
and maximized value. The value is evident from the performance
provided every day.
-
The local stand-alone software provides functions of
basic model, quantitative test, kinetics, and system utilities.
-
System can save research results up to 200 group of
data and 200 curves in the RAM for random check and reload.
Features
-
Large graphic LCD display (128 × 64) to directly show
graphs on the screen, displaying a total of 200 groups of data, 5
groups per screen.
-
Pre-aligned deuterium lamp for easy lamp replacement
to avoid optical adjustment.
-
Automatically check wavelength and photometric
accuracy using validation report.
-
Powerful integrated software for data acquisition:
-
Quantitative
-
Kinetics
-
Wavelength
Scanning
Other features include:
-
System
examination: Automatic wavelength check, automatic light filter
detection, automatic energy detection, and other automatic
functions.
-
Photometric
cutoff: Automatic cutoff of deuterium lamp and halogen lamp to
extend their durability.
-
Power
failure protection: Research data can be saved and restored when
there is power failure.
-
Software:
Application software can be connected to computer to control
equipment operation and to analyze experimental data.
Specifications
|
Model |
V-1600 |
V-1800 |
UV-1600 |
UV-1800 |
|
Optical System |
Single Beam, Grating 1200 lines/mm |
|
Wavelength Range |
320-1100nm |
190-1100nm |
|
Spectral Bandwidth |
4nm |
2nm |
4nm |
2nm |
|
Wavelength Accuracy |
±0.8nm |
|
Wavelength Repeatability |
0.5nm |
|
Photometric Accuracy |
±0.3% T |
|
Photometric Repeatability |
0.2% T |
|
Stray Light |
0.05% T (360nm) |
0.05% T (220nm, 360nm) |
|
Baseline Stability |
±0.002 A/h (500nm) |
|
Display |
LCD |
(128 × 64) |
|
Photometric Mode |
T, A, E |
|
Wavelength Setting |
Automatic |
|
Photometric Range |
-0.3-3 A, 0-200% T |
|
Detector |
Si Photodiode |
|
Light Source |
Tungsten lamp |
Tungsten & Deuterium |
|
Keyboard |
Membrane Keypad |
|
Output |
USB Port & Parallel Port (Printer) |
|
Power Requirement |
AC 220V/50Hz or AC 110V/60Hz |
|
Dimensions |
(W × D × H) |
470mm × 370mm × 180mm |
|
Weight |
|
14Kg |
16Kg |
|
Packing list of UV-1600 and
UV-1800 |
Optional accessories
|
|
Spectrophotometer…………… 1 |
SINGLE CELL HOLDER FOR 10MM SQU.CUVT. |
|
Mains Lead…………………... 1 |
CYLINDRICAL CELL HOLDER |
|
Cuvettes……………………… Set of 4, glass |
TEST TUBE HOLDER (ø8-Ø22mm) |
|
Set of 2, quartz |
LONG PATH CELL HOLDER |
|
User Manual…………………. 1 |
4-CELL HOLDER FOR UP TO 50MM SQU.CUVETTE
|
|
4-CELL HOLDER FOR UP TO 100MM SQU.CUVETTE
|
|
Packing list of V-1600 and
V-1800 |
MICRO CELL HOLDER |
|
Spectrophotometer…………… 1 |
WATER-JACKETED CELL HOLDER |
|
Mains Lead…………………... 1 |
PELTIER/SIPPER SYSTEM |
|
Cuvettes……………………… Set of 4, glass |
PRINTER |
|
User Manual…………………. 1 |
COMMON SOFTWARE FOR 1600 AND 1800 |
|
ADVANCED PC WINDOW SOFTWARE |
|
|
B01- UV-3 Series
Single Beam UV/Vis Spectrophotometer
Descriptions |

|
-
UV-3 Series are advanced single beam design consisting
of 10 models. Different one with different bandwidth and wavelength
accuracy. All of them provide excellent performance for measurement in
the range of 190nm to 1100nm.
-
UV-3 series can be divided into two types—PC Models
and Stand-alone Models, separately offer excellent performance.
-
To Stand-alone
models, all software methods are included as built-in standard, thus
eliminating the need for software options.
-
Online software
upgrade via Internet helps to keep your software up-to-date.
-
Data Download-to-PC
software expands the data storage to unlimited.
The UV-3 series are suitable for clinical lab
applications, pharmaceutical and biochemical as well as routine
applications such as quantitative analyses, kinetics, wavelength
scanning, multiple components and DNA/Protein analysis.
PC Windows® application software and built-in software
make this instrument versatile.
Features
-
PC models and Stand-alone models with large graphic
LCD display (320 × 240) to directly show graphs on the screen.
-
Unique pre-aligned deuterium lamp for easy lamp
replacement to avoid optical adjustment.
-
GLP self-calibrated function can automatically check
wavelength and photometric accuracy using validation report.
-
Powerful integrated software for data acquisition:
-
Quantitative—Establish or use stored calibration equation to measure
the concentration of unknowns.
-
Kinetics—Measurement
of absorbance changing vs. time with reaction rate calculation
function.
-
Wavelength
Scanning—Spectrum scan of sample at any selected wavelength range
with choice of scanning speed and wavelength interval.
-
Multi-Wavelength—Measurement at multiple wavelengths to analyze and
determine the composition of mixtures.
-
DNA/Protein—Calculation of concentration and DNA purity. Ratio at
other wavelengths can be measured.
Other features include:
-
System examination:
Automatic wavelength check, automatic light filter detection,
automatic energy detection, and other automatic functions.
-
Photometric switch:
Able to switch light source in the specific range.
-
Photometric cutoff:
Automatic cutoff of deuterium lamp and halogen lamp to extend their
durability.
-
Power failure
protection: Research data can be saved and restored when there is
power failure.
-
Software: Application
software can be connected to computer to control equipment operation
and to analyze experimental data.
Specifications
|
Model |
UV-3000 |
UV-3100 |
UV-3200 |
UV-3200 S |
UV-3300 |
|
UV-3000 PC |
UV-3100 PC |
UV-3200 PC |
UV-3200 PCS |
UV-3300 PC |
|
Optical System |
Single Beam, Grating 1200 lines/mm |
|
Wavelength Range |
190-1100nm |
|
Spectral Bandwidth |
4.0nm |
2.0nm |
1.8nm |
0.5/1.0/2.0/4.0nm |
1.0nm |
|
Wavelength Accuracy |
±0.5nm |
±0.3nm |
|
Wavelength Repeatability |
0.3nm |
0.2nm |
|
Photometric Accuracy |
±0.3% T |
±0.2% T |
|
Photometric Repeatability |
0.2% T |
0.15% T |
|
Stray Light |
< 0.05% T |
|
Baseline Stability |
±0.002 A/h |
±0.001 A/h |
|
Baseline Flatness |
±0.002 A
(200-1000nm) |
±0.001 A
(200-1000nm) |
|
Display |
LCD (320 × 240)/ PC Model (Please see page 28)
|
|
Photometric Mode |
T, A, E |
|
Scanning Speed |
High, Med., Low. , Max. 3000nm/min
|
|
Wavelength Setting |
Automatic |
|
Photometric Range |
-0.3-3 A, 0-200% T, 0-9999 Conc.
|
|
Detector |
Si Photodiode |
|
Light Source |
Halogen & Deuterium lamp (pre-aligned)
|
|
Keyboard |
Membrane Keypad |
Membrane Keypad or PC |
|
Output |
USB Port & Parallel Port (Printer) |
|
Power Requirement |
AC 220V/50Hz or AC 110V/60Hz |
|
Dimensions (W×D×H)
|
480mm × 360mm × 160mm |
600mm × 450mm × 200mm |
|
Weight |
16Kg |
25Kg |
|
Packing list |
Optional accessories |
|
Spectrophotometer…………… 1 |
SINGLE CELL HOLDER FOR 10MM SQU.CUVT. |
|
Mains Lead…………………... 1 |
CYLINDRICAL CELL HOLDER |
|
Cuvettes……………………… Set of 4, glass |
TEST TUBE HOLDER (ø8-Ø22mm) |
|
Set of 2, quartz |
LONG PATH CELL HOLDER
|
| |
4-CELL HOLDER FOR UP
TO 50MM SQU.CUVETTE |
|
USB Cord |
4-CELL HOLDER FOR UP
TO 100MM SQU.CUVETTE |
|
1 User Manual………………….
1 |
MICRO CELL HOLDER
|
|
UV-Vis Analyst Software……. 1 |
WATER-JACKETED CELL HOLDER |
|
Software Manual…………….. 1 |
PELTIER/SIPPER SYSTEM |
|
* UV3000 and UV-3100 series do not include the
|
8-POSITION AUTO CELL CHANGER |
|
software and USB. |
REFLECTANCE MEACHMENT ATTACHMENT |
|
PRINTER |
|
DONGLES FOR 31.61 APPLICATION SOFTWARE
(UV-3000 and UV-3100) |
|
|
B01- UV-6 Series Double Beam UV/Vis
Spectrophotometer
Descriptions |
 |
-
UV-6 Series are
advanced double beam design consisting of four models; Stand-alone
models: UV6100 with 1.8nm fixed bandwidth and UV6300 with 1.0 fixed
bandwidth; PC models: UV-6100PC with 1.8nm fixed bandwidth and
UV-6300PC with 1.0nm fixed bandwidth. (Other specifications of the
four styles are almost the same except bandwidth)
-
The two detectors are measuring sample and reference
respectively and simultaneously for optimizing measurement accuracy.
They provide accurate measurement in the range of 190nm to 1100nm.
-
All instruments provide excellent performance for
measurements:
-
To Stand-alone
models, all software methods are included as built-in standard, thus
eliminating the need for software options.
-
On-line software
upgrade capability via Internet helps to keep your software
up-to-date.
-
Data Download-to-PC
software expands the data storage to unlimited.
-
This spectrophotometer is suitable for pharmaceutical,
biochemical and clinical lab applications as well as routine
applications such as quantitative analyses, kinetics, spectrum
scanning, multiple components and DNA/Protein analysis.
-
PC Windows® application software and built-in software
make this instrument versatile.
Features
-
PC models and Stand-alone models with large graphic
LCD display (320 × 240) to directly show graphs on the screen.
-
Unique pre-aligned deuterium lamp for easy lamp
replacement to avoid optical adjustment.
-
GLP self-calibrated function can automatically check
wavelength and photometric accuracy using validation report.
-
Powerful integrated software for data acquisition:
-
Quantitative
-
Kinetics
-
Wavelength Scanning
-
Multi-Wavelength
-
DNA/Protein
Other features include:
-
System examination:
Automatic wavelength check, automatic light filter detection,
automatic energy detection, and other automatic functions.
-
Photometric switch:
Able to switch light source in the specific range.
-
Photometric cutoff:
Automatic cutoff of deuterium lamp and halogen lamp to extend their
durability.
-
Power failure
protection: Research data can be saved and restored when there is
power failure.
-
Software: Application
software can be connected to computer to control equipment operation
and analyze experimental data.
Specifications
|
Model |
UV-6100 |
UV-6100 PC |
UV-6300 |
UV-6300 PC |
|
Optical System |
Double Beam, Grating 1200 lines/mm |
|
Wavelength Range |
190-1100nm |
190-1100nm |
|
Spectral Bandwidth |
1.8nm |
1.0nm |
|
Wavelength Accuracy |
±0.3nm |
|
Wavelength Repeatability |
0.2nm |
|
Photometric Accuracy |
±0.2% T |
|
Photometric Repeatability |
0.15% T |
|
Stray Light |
< 0.05% T |
|
Baseline Stability |
±0.0005 A/h |
|
Baseline Flatness |
±0.0005 A (200-1000nm) |
|
Display |
LCD (320 × 240) &
PC Model |
PC Model |
LCD (320 × 240) &
PC Model |
PC Model |
|
|
Photometric Mode |
T, A, E |
|
Scanning Speed |
High, Med., Low. , Max. 3000nm/min |
|
Wavelength Setting |
Automatic |
|
Photometric Range |
-0.3-3 A, 0-200% T, 0-9999 Conc. |
|
Detector |
Si Photodiode |
|
Light Source |
Halogen & Deuterium Lamp (pre-aligned) |
|
Keyboard |
Membrane Keypad or PC |
|
Output |
USB Port & Parallel Port (Printer) |
|
Power Requirement |
AC 220V/50Hz or AC 110V/60Hz |
|
Dimensions |
(W × D × H) |
600mm × 450mm × 200mm |
|
Weight |
|
27Kg |
27Kg |
|
Packing list
|
Optional accessories
|
|
Spectrophotometer…………… 1 |
SINGLE CELL HOLDER FOR 10MM SQU.CUVT. |
|
Mains Lead…………………... 1 |
CYLINDRICAL CELL HOLDER |
|
Cuvettes……………………… Set of 4, glass |
TEST TUBE HOLDER (ø8-Ø22mm) |
|
Set of 2, quartz |
LONG PATH CELL HOLDER |
|
USB Cord 1 |
4-CELL HOLDER FOR UP TO 50MM SQU.CUVETTE
|
|
User Manual…………………. 1 |
4-CELL HOLDER FOR UP TO 100MM SQU.CUVETTE
|
|
UV-Vis Analyst Software……. 1 |
MICRO CELL HOLDER |
|
Software Manual…………….. 1 |
WATER-JACKETED CELL HOLDER |
|
PELTIER/SIPPER SYSTEM |
|
8-POSITION AUTO CELL CHANGER |
|
REFLECTANCE MEACHMENT ATTACHMENT |
|
PRINTER |
|
|
Model |
Optical System |
Wavelength
Range |
Spectral
Bandwidth |
Kinetics |
DNA/Protein |
Scanning |
Display |
PC Software |
| UV-6300 |
Double
Beam |
190~1100nm |
1nm |
O |
O |
O |
LCD
320*240 |
O |
|
UV-6300PC |
Double Beam |
190~1100nm |
1nm |
O |
O |
O |
X |
O |
|
UV-6100 |
Double Beam |
190~1100nm |
1.8nm |
O |
O |
O |
LCD 320*240 |
O |
|
UV-6100PC |
Double Beam |
190~1100nm |
1.8nm |
O |
O |
O |
X |
O |
|
UV-3300 |
Single
Beam |
190~1100nm |
1nm |
O |
O |
O |
LCD 320*240 |
O |
|
UV-3300PC |
Single Beam |
190~1100nm |
1nm |
O |
O |
O |
X |
O |
|
UV-3200S |
Single Beam |
190~1100nm |
0.5/1.0/2.0/4.0nm |
O |
O |
O |
LCD 320*240 |
O |
|
UV-3200PCS |
Single Beam |
190~1100nm |
0.5/1.0/2.0/4.0nm |
O |
O |
O |
X |
O |
|
UV-3200 |
Single Beam |
190~1100nm |
1.8nm |
O |
O |
O |
LCD 320*240 |
O |
|
UV-3200PC |
Single Beam |
190~1100nm |
1.8nm |
O |
O |
O |
X |
O |
|
UV-3100 |
Single Beam |
190~1100nm |
2nm |
O |
O |
O |
LCD 320*240 |
X |
|
UV-3100PC |
Single Beam |
190~1100nm |
2nm |
O |
O |
O |
LCD 320*240 |
O |
|
UV-3000 |
Single Beam |
190~1100nm |
4nm |
O |
O |
O |
LCD 320*240 |
X |
|
UV-1800 |
Single Beam |
190~1100nm |
2nm |
O |
X |
X |
LCD 128*64 |
X |
|
UV-1800PC |
Single Beam |
190~1100nm |
2nm |
O |
O (PC only) |
PC
Software |
LCD 128*64 |
O |
|
UV-1600 |
Single Beam |
190~1100nm |
4nm |
O |
X |
X |
LCD 128*64 |
X |
|
UV-1600PC |
Single Beam |
190~1100nm |
4nm |
O |
O (PC only) |
PC Software |
LCD 128*64 |
O |
|
UV-1200 |
Single Beam |
200~1100nm |
4nm |
X |
X |
X |
LCD 128*64 |
X |
|
UV-1100 |
Single Beam |
200~1100nm |
5nm |
X |
X |
X |
LCD 128*64 |
X |
|
V-1800 |
Single Beam |
320~1100nm |
2nm |
O |
X |
X |
LCD 128*64 |
X |
|
V-1800PC |
Single Beam |
320~1100nm |
2nm |
O |
X |
PC Software |
LCD 128*64 |
O |
|
V-1600 |
Single Beam |
320~1100nm |
4nm |
O |
X |
v |
LCD 128*64 |
X |
|
V-1600PC |
Single Beam |
320~1100nm |
4nm |
O |
X |
PC Software |
LCD 128*64 |
O |
|
V-1200 |
Single Beam |
325~1100nm |
4nm |
X |
X |
X |
LCD 128*64 |
X |
|
V-1100 |
Single Beam |
325~1100nm |
5nm |
X |
X |
X |
3.5
bits LCD |
X |
|
|