B01- CT-8 Series Double Beam UV/Vis
Spectrophotometer
| Features
A. PC
models and
Stand-alone
models with large graphic LCD display
(320 × 240) to directly show graphs on the screen.
B.
Unique pre-aligned deuterium
lamp for easy lamp replacement
to avoid optical adjustment.
C. GLP
self-calibrated function can automatically
check wavelength and photometric
accuracy using validation
report.
D.
Powerful integrated software
for data acquisition:
-
Quantitative
-
Kinetics
-
Wavelength Scanning
-
Multi-Wavelength
-
DNA/Protein
|
 |
E. Other features include:
-
System examination:
Automatic wavelength
check, automatic light
filter detection, automatic
energy detection, and other automatic
functions.
-
Photometric switch: Able to switch light source in the specific range.
-
Photometric cutoff:
Automatic cutoff
of deuterium lamp
and halogen lamp to extend their durability.
-
Power failure protection: Research data can be
saved and restored when there is power failure.
-
Software: Application software can be connected to computer
to control equipment operation
and analyze experimental
data.
Specifications
|
Model |
CT-8200 |
CT-8100 |
CT-8600 |
CT-8700 |
|
Optical System |
Double Beam, Grating 1200
lines/mm |
|
Wavelength
Range |
190-1100nm |
190-1100nm |
|
Spectral Bandwidth |
1.8nm |
1.0nm |
|
Wavelength
Accuracy |
±0.3nm |
|
Wavelength
Repeatability |
0.2nm |
|
Photometric Accuracy |
±0.2% T |
|
Photometric
Repeatability |
0.15%
T |
|
Stray
Light |
<0.05% T |
|
Baseline Stability |
±0.0005
A/h |
|
Baseline Flatness |
±0.0005
A (200-1000nm) |
|
Display |
LCD
(320 × 240)
&
PC
Model |
PC
Model |
LCD
(320 × 240)
&
PC
Model |
PC
Model |
|
Photometric
Mode |
T,
A, E |
|
Scanning
Speed |
High,
Med.,
Low.
,
Max.
3000nm/min |
|
Wavelength
Setting |
Automatic |
|
Photometric
Range |
-0.3-3
A, 0-200%
T,
0-9999
Conc. |
|
Detector |
Si Photodiode |
|
Light Source |
Halogen & Deuterium
Lamp
(pre-aligned) |
|
Keyboard |
Membrane
Keypad
or PC |
|
Output |
USB Port
& Parallel
Port (Printer) |
|
Power
Requirement |
AC
220V/50Hz
or AC
110V/60Hz |
|
Dimensions (W
× D ×
H) |
600mm
× 450mm
× 200mm |
|
Weight |
27Kg |
27Kg |
B01- CT-5, CT-6 Series Single Beam
UV/Vis Spectrophotometer
Features
A.
PC
models and
Stand-alone
models
with large
graphic LCD display
(320 × 240)
to
directly
show graphs on
the
screen.
B.
Unique pre-aligned deuterium
lamp for easy
lamp
replacement
to avoid optical adjustment.
|
C.
GLP
self-calibrated
function can automatically
check wavelength
and photometric
accuracy
using validation report.
D.
Powerful integrated software
for data acquisition:
-
Quantitative—Establish or use stored calibration equation
to measure the
concentration of unknowns.
-
DNA/Protein—Calculation
of concentration and DNA
purity.
Ratio at other wavelengths
can be measured.
-
Kinetics—Measurement
of absorbance changing vs.
time
with reaction rate calculation
function.
-
Wavelength Scanning—Spectrum scan of sample
at any selected wavelength
range with choice
of
scanning speed and wavelength interval.
-
Multi-Wavelength—Measurement
at
multiple
wavelengths to analyze
and determine
the
composition of mixtures.
|
 |
F.
Other features include:
-
System
examination: Automatic
wavelength check, automatic
light filter detection, automatic
energy detection, and other automatic
functions.
-
Photometric switch:
Able to switch light source in the specific range.
-
Photometric cutoff:
Automatic
cutoff of
deuterium lamp
and halogen lamp
to extend their durability.
-
Power
failure protection: Research
data can be saved and
restored when there is power failure.
-
Software: Application software
can be connected to computer
to control equipment
operation and to analyze
experimental
data.
Specifications
|
Model |
CT-5000
CT-5100
|
CT-5600
CT-5700 |
CT-6200
CT-6100 |
CT-6400
CT-6300 |
CT-6600
CT-6500 |
|
Optical System |
Single Beam<,
Grating 1200 lines/mm |
|
Wavelength
Range |
190-1100nm |
|
Spectral
Bandwidth |
4.0nm |
2.0nm |
1.8nm |
0.5/1.0/2.0/4.0nm |
1.0nm |
|
Wavelength
Accuracy |
±0.5nm |
±0.3nm |
|
Wavelength
Repeatability |
0.3nm |
0.2nm |
|
Photometric
Accuracy |
±0.3%T |
±0.2%
T |
|
Photometric
Repeatability |
0.2%T |
0.15% T |
|
Stray
Light |
<0.05%
T |
|
Baseline
Stability |
±0.002 A/h |
±0.001 A/h |
|
Baseline
Flatness |
±0.002 A (200-1000nm) |
±0.001
A (200-1000nm) |
|
Display |
LCD (320
× 240) / PC Model
(Please see the last page) |
|
Photometric
Mode |
T, A, E |
|
Scanning
Speed |
High,
Med.,
Low.
,
Max.
3000nm/min |
|
Wavelength
Setting |
Automatic |
|
Photometric
Range |
-0.3-3
A, 0-200%
T,
0-9999
Conc. |
|
Detector |
Si Photodiode |
|
Light Source |
Halogen & Deuterium
lamp
(pre-aligned) |
|
Keyboard |
Membrane
Keypad
(CT-5000,
CT-5600)
Membrane
Keypad
or PC (CT-5100,
CT-5700,
CT-6100,
CT-6200,
CT-6300,
CT-6400,
CT-6500,
CT-6600)
|
|
Output |
USB Port & Parallel Port
(Printer) |
|
Power
Requirement |
AC 220V/50Hz
or AC 110V/60Hz |
|
Dimensions
(W × D
× H) |
480mm
× 360mm
× 160mm |
600mm
× 450mm
× 200mm |
|
Weight |
16Kg |
25Kg |
B01- CT-2500-2800 Series Spectrophotometer
| Features
C. Large
graphic LCD display (128 × 64) to directly
show graphs on the screen,
displaying a total of 200
groups of data, 5 groups per screen.
B. Pre-aligned deuterium
lamp for easy lamp
replacement to avoid
optical adjustment.
C. Automatically
check wavelength and photometric
accuracy using validation
report.
D.
Powerful integrated software
for data acquisition:
-
Quantitative
-
Kinetics
-
Wavelength
Scanning
|
 |
F. Other features include:
-
System examination:
Automatic wavelength
check, automatic light
filter detection, automatic
energy detection, and other automatic
functions.
-
Photometric cutoff: Automatic
cutoff of deuterium
lamp and halogen lamp to
extend their durability.
-
Power failure protection: Research data can be
saved and restored when there is power failure.
-
Software: Application software can be connected to computer
to control equipment operation
and to analyze experimental
data.
Specifications
|
Model |
CT-2500 |
CT-2700 |
CT-2600 |
CT-2800 |
|
Optical System |
Single Beam, Grating 1200 lines/mm |
|
Wavelength
Range |
320-1100nm |
190-1100nm |
|
Spectral Bandwidth |
4nm |
2nm |
4nm |
2nm |
|
Wavelength
Accuracy |
±0.8nm |
|
Wavelength
Repeatability |
0.5nm |
|
Photometric
Accuracy |
±0.3% T |
|
Photometric
Repeatability |
0.2% T |
|
Stray Light |
0.05%
T (360nm) |
0.05%
T (220nm,
360nm) |
|
Baseline
Stability |
±0.002 A/h (500nm) |
|
Display |
LCD (128 ×
64) |
|
Photometric
Mode |
T, A, E |
|
Wavelength
Setting |
Automatic |
|
Photometric
Range |
-0.3-3
A, 0-200%
T |
|
Detector |
Si Photodiode |
|
Light Source |
Tungsten
lamp |
Tungsten
& Deuterium |
|
Keyboard |
Membrane
Keypad |
|
Output |
USB
Port &
Parallel Port (Printer) |
|
Power Requirement |
AC 220V/50Hz
or AC
110V/60Hz |
|
Dimensions
(W × D
× H) |
470mm
× 370mm
× 180mm |
|
Weight |
14Kg |
16Kg |
B01- CT-2300/CT-2400 Series
Spectrophotometer\
|
Features
A. Large
graphic LCD display (128 × 64) to directly
show graphs on the screen,
displaying a total of 50
groups of data and being able to save the research data.
B. Pre-aligned deuterium
lamp for easy lamp
replacement to avoid
optical adjustment.
C. Power failure protection:
Research data can be saved
and restored when there is power failure.
D.
Automatically
check wavelength and photometric
accuracy using validation
report.
E. Powerful integrated
software for data acquisition for basic measurement
and analysis.
F. Other
features include spectrum
test, wavelength check, standard
curve, and application
software.
|
 |
Specifications
|
Model |
CT-2300 |
CT-2400 |
|
Optical System |
Single Beam, Grating 1200 lines/mm |
|
Wavelength
Range |
325-1000nm |
200-1100nm |
|
Spectral Bandwidth |
4nm |
|
Wavelength
Accuracy |
±1nm |
|
Wavelength
Repeatability |
1nm |
|
Photometric
Accuracy |
±0.5% T |
|
Photometric
Repeatability |
0.3% T |
|
Stray Light |
0.3%T |
|
Baseline
Stability |
±0.004 A/h (500nm) |
|
Display |
LCD (128 ×
64) |
|
Photometric
Mode |
T, A, E |
|
Wavelength
Setting |
Automatic |
|
Photometric
Range |
-0.097-2.5
A, 0-125%
T |
|
Detector |
Si Photodiode |
|
Keyboard |
Membrane
Keypad |
|
Light Source |
Tungsten
lamp |
Tungsten
& Deuterium |
|
Output |
USB
Port &
Parallel Port (Printer) |
|
Power Requirement |
AC 220V/50Hz
or AC
110V/60Hz |
|
Dimensions
(W × D ×
H) |
470
× 370
× 180mm |
|
Weight |
12Kg |
12Kg |
B01- CT-1500/CT-2200
Spectrophotometer

CT-2200 |

CT-1500 |
Features
A.
High quality
silicon photometric
diode
detector and 1200 lines/mm
grating ensure high accuracy and
precision.
B. Digital display for easy
readout.
C. Pre-aligned deuterium
lamp for easy lamp
replacement to avoid
optical adjustment.
D.
Auto zero setting
for easy
use and simple switch to transmittance,
absorbance and concentration
models.
E. With
RS-232C port, data can be exported to printer directly.
F. Optional software based on
Windows®
can extend the application to
standard curve and kinetics
through the RS-232C port.
Besides features mentioned above,
CT-2200 contains other
features include:
A.
Large
LCD display (128 × 64)
B. Able to display and save 50
groups of data, 3 groups per screen.
C. Data can be saved and restored
when there is sudden power failure.
D.
Three-point
method
to measure
concentration of unknown
samples.
E. Automatic
cutoff of deuterium lamp
and halogen lamp
to extend their durability.
|
Model |
CT-1500 |
CT-2200 |
|
Optical System |
Single Beam, Grating 1200 lines/mm |
|
Wavelength
Range |
325-1000nm |
200-1000nm |
|
Spectral Bandwidth |
5nm |
|
Wavelength
Accuracy |
±2nm |
|
Wavelength
Repeatability |
1nm |
|
Photometric
Accuracy |
±0.5% T |
|
Photometric
Repeatability |
0.3% T |
|
Stray Light |
0.5% T |
|
Baseline
Stability |
±0.004 A/h (500nm) |
|
Display |
3.5
bits LCD |
LCD (128 ×
64) |
|
Photometric
Mode |
T, A, E |
|
Wavelength
Setting |
Manual |
Automatic |
|
Photometric
Range |
-0.097-1.999
A,
0-125%
T |
|
Detector |
Si Photodiode |
|
Light Source |
Tungsten
lamp |
Tungsten
& Deuterium |
|
Keyboard |
Membrane
Keypad |
|
Output |
RS-232C
Port |
USB Port & Parallel Port
(Printer) |
|
Power Requirement |
AC 220V/50Hz
or AC
110V/60Hz |
|
Dimensions
(W × D
× H) |
480mm
× 360mm
× 160mm |
470mm
× 370mm
× 180mm |
|
Weight |
8Kg |
12Kg |
|